SEARCH

The Products Section >Portable / Survey Monitoring Applications

Interscan's portable gas analyzers are available for Br2, CO, Cl2, ClO2, C2H4, ethylene oxide, HCHO, H2, hydrazine, HBr, HCl, HCN, H2S, NO, NO2, O3, propylene oxide, and SO2.

Our portable gas analyzers utilize Interscan's own patented (US Patent Number 4,017,373) electrochemical voltametric sensors.

4000 Series Portable Gas Analyzers
 
photo
Click Here For Larger View

Features

  • An integral sample pump, powered by rechargeable Ni-Cd batteries (supplied), giving up to 10 hours of continuous service
  • Digital readout of concentration in real time
  • Audible and visual alarm
  • Nylon/Cordura carrying case
  • Plug-in "calculator-type" battery charger
  • UL Classified Intrinsically Safe models, for use in hazardous locations, Class I, Groups A, B, C, and D (10X0), are available. Please consult factory.
  • Analog output (0-100 mV full scale)
  • CE Approved models available, please consult factory.
 

Options

  • Special ranges
  • Special packaging

Additional Specs

Resolution
0-1999 ppm range1 ppm
0-199.9 ppm range 0.1ppm
0-19.99 ppm range0.01ppm
ppb ranges 1 ppb

Weight:
4.5 lb (2.0 kg)

Dimensions:
7" H x 4" W x 8.875" D
(178 x 102 x 225 mm)

Specifications common to all Interscan gas detection instruments

 

Range Table and Ordering Information for 4000 Series Portable Gas Analyzers

GAS
MODEL NO. †
STANDARD MEASURING RANGES
(ppm, unless otherwise indicated)
Br2
bromine
4700-1999m
4700-199.9m
4700-19.99m
4700-1999b
0-1999
0-199.9
0-19.99
0-1999 ppb
CO
carbon monoxide
4140-1999m
4140-199.9m
4140-19.99m
0-1999
0-199.9
0-19.99
Cl2
chlorine
4340-1999m
4340-199.9m
4340-19.99m 4340-1999b
0-1999
0-199.9
0-19.99
0-1999 ppb
ClO2
chlorine dioxide
4330-1999m
4330-199.9m
4330-19.99m
4330-1999b
4330-1000b
0-1999
0-199.9
0-19.99
0-1999 ppb
0-1000 ppb
C2H4
ethylene
4070-1999m
4070-199.9m
4070-19.99m
4070-5m
0-1999
0-199.9
0-19.99
0-5
EtO
ethylene oxide
4200-1999m
4200-199.9m
4200-19.99m
4200-1999b
0-1999
0-199.9
0-19.99
0-1999 ppb
HCHO
formaldehyde
4160-1999m
4160-199.9m
4160-19.99m
4160-1999b
4160-500b
0-1999
0-199.9
0-19.99
0-1999 ppb
0-500 ppb
H2NNH2
CH3NHNH2
(CH3)2NNH2
hydrazine(s) ¶
4180-1999m
4180-199.9m
4180-19.99m
4180-1999b
4180-100b
4183¤
4186¤
4187¤
4189¤
0-1999
0-199.9
0-19.99
0-1999 ppb
0-100 ppb
0-0.5/0-2
0-2/0-10
0-100/0-2000 ppb
0-100/0-1000 ppb
H2
hydrogen
4020-1999m
4020-199.9m
0-1999
0-199.9
HBr
hydrogen bromide
4800-1999m
4800-199.9m
4800-19.99m
4800-1999b
0-1999
0-199.9
0-19.99
0-1999 ppb
HCl
hydrogen chloride
4360-1999m
4360-199.9m
4360-19.99m
4360-1999b
0-1999
0-199.9
0-19.99
0-1999 ppb
HCN
hydrogen cyanide
4280-1999m
4280-199.9m
4280-19.99m
4280-1999b
0-1999
0-199.9
0-19.99
0-1999 ppb
H2S
hydrogen sulfide
4170-1999m
4170-199.9m
4170-19.99m
4170-1999b
4170-1000b
4170-500b
0-1999
0-199.9
0-19.99
0-1999 ppb
0-1000 ppb
0-500 ppb
NO
nitric oxide
4540-1999m
4540-199.9m
4540-19.99m
4540-1999b
0-1999
0-199.9
0-19.99
0-1999 ppb
NO2
nitrogen dioxide

Also known as N2O4
nitrogen tetroxide
4150-1999m
4150-199.9m
4150-19.99m
4150-1999b
4152¤
4154¤
0-1999
0-199.9
0-19.99
0-1999 ppb
0-2/10
0-10/0-50
O3
ozone
4480-1999m
4480-199.9m
4480-19.99m
4480-1999b
0-1999
0-199.9
0-19.99
0-1999 ppb
PrO
propylene oxide
4320-1999m
4320-199.9m
4320-19.99m
4320-1000b
0-1999
0-199.9
0-19.99
0-1000 ppb
SO2
sulfur dioxide
4240-1999m
4240-199.9m
4240-19.99m
4240-1999b
0-1999
0-199.9
0-19.99
0-1999 ppb

  † These are the new model numbers. Certain other sources may not reflect this system, while the changeover is occurring. If in doubt, specify the gas and the measuring range desired.

  ¶ There is not a separate analyzer available for each of these compounds, and the sensor does not respond equally to all hydrazine species. The analyzer must be calibrated with the specific hydrazine compound of interest.

  ¤ Indicates the analog meter UL classified intrinsically safe version, which must be ordered in most hypergol monitoring applications.


  

 P.O. Box 2496 • Chatsworth, CA 91313-2496
 TOLL FREE: (800) 458-6153 (US & Canada) • PHONE: (818) 882-2331
 FAX: (818) 341-0642 • E-MAIL: info@gasdetection.com

 Home Page
 Products
     • Portable Survey
          Monitoring Applications

     • Continuous Monitoring-
          Single Point

     • Continuous Monitoring-
          Two Point

     • Automation Based Gas
          Detection Systems

     • Continuous Monitoring-
          Three Or More Points

     • Arc-Max® Computerized
          Data Acquisition System

     • The Halimeter® Measure
          Bad Breath Scientifically

     • Inexpensive, Accurate,
          Nomad Data Logger

     • Vikane® Monitor
 Tech Center
     • Common Specifications
     • Ethylene Oxide     
     • FAQ - Instrument
          Troubleshooting

     • Gas Detection
          Applications Primer

     • Gas Detection
          Knowledge Base

     • General Considerations
     • Getting Service
     • How Do I Get Started?
     • Halimeter®
     • Interfering Gas Data
     • Manual Downloads
     • Material Safety Data Sheets
     • PowerPoint Presentations
     • Schematics
     • Sensor Principle of Operation
     • Sensor Response Data
     • Software Downloads
     • Toxnet - HSDB
     • Useful formulae--
          Conversions, etc.

Industry Links
Interscan In The News
     • Magazine Articles
Representatives and
     Distributors Worldwide

Special Interest Items
     • Mike's Comment
          of the Week

     • Cool Site of the Week
Interscan Photo Gallery
 Streaming Media Library
E-mail Us



Sign up here for our newsletter. (Your e-mail address will NEVER be given or sold to any other party)

e-mail
    Subscribe
    Unsubscribe


Copyright ©1996 - 2008
Interscan Corporation.
All rights reserved.

All other trademarks are
the property of their
respective owners.