The Products Section >Continuous Monitoring - Single Point Applications
If you need to perform gas detection at only one point, or have several points that are either widely separated, or would each be better served by a self-contained monitoring system, check out Interscan's LD or RM Series. These tough, field-proven units are available for Br2, CO, Cl2, ClO2, C2H4, ethylene oxide, HCHO, H2, hydrazine, HBr, HCl, HCN, H2O2, H2S, NO, NO2, O3, propylene oxide, and SO2.
-- and use our own patented electrochemical voltametric sensors.
| LD
Series |
| |

Click Here for Larger View |
Interscan's LD Series represents the ultimate in single point continuous gas monitoring systems. Each and every component has been chosen based on years of experience in some of the most demanding environments imaginable. What's more, the units are easy and inexpensive to maintain.
An impressive array of options allows the specifier to put together a system ideally suited to the application at hand.
|
| |
Options
- Alternative packaging, including Type X or Type Z purged enclosures and RFI resistant enclosures
- Audible alarm
- Visual alarm
- Enclosure heating and cooling
- Loss of flow alarm
- Triple alarm set points
- Loss of power alarm
- Aspirator (in lieu of pump)
- Auto zero
- Sensor protection circuit
|
|
Features
- Super-rugged NEMA Type 4X fiberglass reinforced polyester enclosure
- 3½ digit LED display
- Integral diaphragm pump
- Rotameter
- Analog output---
0-1 V & 4-20 mA full scale
- Low and high alarm contacts, continuously adjustable through the full scale measuring range, activating dedicated relays
Additional Specs
Resolution
| 0-2000 ppm range |
1 ppm |
| 0-1000 ppm range |
1 ppm |
| 0-500 ppm range |
1 ppm |
| 0-200.0 ppm range |
0.1 ppm |
| 0-100.0 ppm range |
0.1 ppm |
| 0-50.0 ppm range |
0.1 ppm |
| 0-20.0 ppm range |
0.1 ppm |
| 0-5.00 ppm range |
0.01 ppm |
| 0-2.00 ppm range |
0.01 ppm |
| 0-1.00 ppm range |
0.01 ppm |
Weight:
22 lb (10.0 kg)
Dimensions:
22" H x 18" W x 8.5" D
(559 x 457x 216 mm)
Specifications common to all Interscan gas detection instruments |
| |
|
| RM Series |
| |
Interscan's Rack-Mount configured gas analyzers are intended for those applications in which line power operation is desired (allowing continuous operation and the incorporation of heavier-duty alarm signals or alarm contacts), but in which the rigorous NEMA 4X packaging of the LD Series is not required.
Designed to be installed in a standard 19 inch (483 mm) rack or to be used on the bench, their open frame construction and use of standard electrical and pneumatic components allow easy incorporation of the units into a system. Many of the LD Series' features and options are available. |
| |
Options
- Integral pump
- Rotameter
- Loss of flow alarm
- 4-20 mA analog output
- Alarm contacts
- Dual alarm set points
- Triple alarm set points
- Loss of power alarm
- Slide rail hardware and access door, for rack mounting
|
|
Features
- 3½ digit LED display
- Wrap-around cover
- 0-1 V analog output
Additional Specs
Resolution
| 0-2000 ppm range |
1 ppm |
| 0-1000 ppm range |
1 ppm |
| 0-500 ppm range |
1 ppm |
| 0-200.0 ppm range |
0.1 ppm |
| 0-100.0 ppm range |
0.1 ppm |
| 0-50.0 ppm range |
0.1 ppm |
| 0-20.0 ppm range |
0.1 ppm |
| 0-5.00 ppm range |
0.01 ppm |
| 0-2.00 ppm range |
0.01 ppm |
| 0-1.00 ppm range |
0.01 ppm |
Weight:
8 lb (3.6 kg)
Dimensions:
7" H x 19" W x 12" D
(178 x 483 x 305 mm)
Specifications common to all Interscan gas detection instruments |
| |
|
Ordering
Information:
LD Series Continuous Gas Monitoring Systems and
RM Series Rack Mount Gas Analyzers
| GAS |
MEASURING
RANGE (ppm) |
LD SERIES Model No. † |
RM SERIES Model No. † |
Br2
bromine |
0-20.0
0-5.00 |
LD70-20.0m
LD70-5.00m |
RM70-20.0m
RM70-5.00m |
CO
carbon monoxide |
0-2000
0-200.0
0-100.0
0-50.0 |
LD14-2000m
LD14-200.0m
LD14-100.0m
LD14-50.0m |
RM14-2000m
RM14-200.0m
RM14-100.0m
RM14-50.0m |
Cl2
chlorine |
0-20.0
0-5.00 |
LD34-20.0m
LD34-5.00m |
RM34-20.0m
RM34-5.00m |
ClO2
chlorine dioxide |
0-20.0
0-5.00
0-2.00 |
LD33-20.0m
LD33-5.00m
LD33-2.00m |
RM33-20.0m
RM33-5.00m
RM33-2.00m |
C2H4
ethylene |
0-2000
0-200.0
0-20.0
0-5.00 |
LD07-2000m
LD07-200.0m
LD07-20.0m
LD07-5.00m |
RM07-2000m
RM07-200.0m
RM07-20.0m
RM07-5.00m |
EtO
ethylene oxide |
0-50.0
0-20.0
0-5.00 |
LD20-50.0m
LD20-20.0m
LD20-5.00m |
RM20-50.0m
RM20-20.0m
RM20-5.00m |
HCHO
formaldehyde |
0-20.0
0-2.00 |
LD16-20.0m
LD16-2.00m |
RM16-20.0m
RM16-2.00m |
H2NNH2
CH3NHNH2
(CH3)2NNH2
hydrazine(s) ¶ |
0-20.0
0-2.00 |
LD18-20.0m
LD18-2.00m |
RM18-20.0m
RM18-2.00m |
H2 hydrogen |
0-2000
0-500 |
LD02-2000m
LD02-500m |
RM02-2000m
RM02-500m |
HBr hydrogen bromide |
0-20.0
0-5.00
|
LD80-20.0m
LD80-5.00m
|
RM80-20.0m
RM80-5.00m
|
HCl
hydrogen chloride |
0-20.0
0-5.00 |
LD36-20.0m
LD36-5.00m |
RM36-20.0m
RM36-5.00m |
HCN
hydrogen cyanide |
0-50.0
0-20.0
0-5.00 |
LD28-50.0m
LD28-20.0m
LD28-5.00m |
RM28-50.00m
RM28-20.0m
RM28-5.00m |
H2O2
hydrogen peroxide |
0-1000
0-200.0
0-50.0
0-5.00
|
LD09-1000m
LD09-200.0m
LD09-50.0m
LD09-5.00m
|
RM09-1000m
RM09-200.0m
RM09-50.0m
RM09-5.00m
|
H2S
hydrogen sulfide |
0-500
0-200.0
0-20.0
0-1.00 |
LD17-500m
LD17-200.0m
LD17-20.0m
LD17-1.00m |
RM17-500m
RM17-200.0m
RM17-20.0m
RM17-1.00m |
NO nitric oxide |
0-2000
0-200.0
0-20.0
0-5.00
|
LD54-2000m
LD54-200.0m
LD54-20.0m
LD54-5.00m |
RM54-2000m
RM54-200.0m
RM54-20.0m
RM54-5.00m |
NO2
nitrogen dioxide Also known as N2O4
nitrogen tetroxide |
0-50.0
0-20.0
0-5.00 |
LD15-50.0m
LD15-20.0m
LD15-5.00m |
RM15-50.0m
RM15-20.0m
RM15-5.0m |
O3
ozone |
0-50.0
0-20.0
0-5.00
|
LD48-50.0m
LD48-20.0m
LD48-5.00m
|
RM48-50.0m
RM48-20.0m
RM48-5.00m |
PrO
propylene oxide |
0-50.0
0-20.0
0-5.00 |
LD32-50.0m
LD32-20.0m
LD32-5.00m |
RM32-50.0m
RM32-20.0m
RM32-5.00m |
SO2
sulfur dioxide |
0-200.0
0-50.0
0-20.0
0-5.00
|
LD24-200.0m
LD24-50.0m
LD24-20.0m
LD24-5.00m
|
RM24-200.0m
RM24-50.0m
RM24-20.0m
RM24-5.00m
|
† These are the new model numbers. Certain other sources may not reflect this system, while the changeover is occurring. If in doubt, specify the gas and the measuring range desired.
¶ There is not a separate analyzer available for each of these compounds, and the sensor does not respond equally to all hydrazine species. The analyzer must be calibrated with the specific hydrazine compound of interest.
Special ranges available on request—The panel meter can be factory programmed to display any desired full scale range, within the measuring capability of the instrument.
|