The Products Section >Continuous Monitoring - Single Point Applications

If you need to perform gas detection at only one point, or have several points that are either widely separated, or would each be better served by a self-contained monitoring system, check out Interscan's LD or RM Series. These tough, field-proven units are available for Br2, CO, Cl2, ClO2, C2H4, ethylene oxide, HCHO, H2, hydrazine, HBr, HCl, HCN, H2O2, H2S, NO, NO2, O3, propylene oxide, and SO2.

-- and use our own patented electrochemical voltametric sensors.

 

LD Series
  photo
Click Here for Larger View

Interscan's LD Series represents the ultimate in single point continuous gas monitoring systems. Each and every component has been chosen based on years of experience in some of the most demanding environments imaginable. What's more, the units are easy and inexpensive to maintain.

An impressive array of options allows the specifier to put together a system ideally suited to the application at hand.

 

 

Options

  • Alternative packaging, including Type X or Type Z purged enclosures and RFI resistant enclosures
  • Audible alarm
  • Visual alarm
  • Enclosure heating and cooling
  • Loss of flow alarm
  • Triple alarm set points
  • Loss of power alarm
  • Aspirator (in lieu of pump)
  • Auto zero
  • Sensor protection circuit
 

Features

  • Super-rugged NEMA Type 4X fiberglass reinforced polyester enclosure
  • 3½ digit LED display
  • Integral diaphragm pump
  • Rotameter
  • Analog output---
      0-1 V & 4-20 mA full scale
  • Low and high alarm contacts, continuously adjustable through the full scale measuring range, activating dedicated relays

Additional Specs

Resolution

0-2000 ppm range 1 ppm
0-1000 ppm range 1 ppm
0-500 ppm range 1 ppm
0-200.0 ppm range 0.1 ppm
0-100.0 ppm range 0.1 ppm
0-50.0 ppm range 0.1 ppm
0-20.0 ppm range 0.1 ppm
0-5.00 ppm range 0.01 ppm
0-2.00 ppm range 0.01 ppm
0-1.00 ppm range 0.01 ppm

Weight:
22 lb (10.0 kg)

Dimensions:
22" H x 18" W x 8.5" D
(559 x 457x 216 mm)

Specifications common to all Interscan gas detection instruments

 

RM Series
 
photo

Interscan's Rack-Mount configured gas analyzers are intended for those applications in which line power operation is desired (allowing continuous operation and the incorporation of heavier-duty alarm signals or alarm contacts), but in which the rigorous NEMA 4X packaging of the LD Series is not required.

Designed to be installed in a standard 19 inch (483 mm) rack or to be used on the bench, their open frame construction and use of standard electrical and pneumatic components allow easy incorporation of the units into a system. Many of the LD Series' features and options are available.

 

Options

  • Integral pump
  • Rotameter
  • Loss of flow alarm
  • 4-20 mA analog output
  • Alarm contacts
  • Dual alarm set points
  • Triple alarm set points
  • Loss of power alarm
  • Slide rail hardware and access door, for rack mounting

 

 

Features

  • 3½ digit LED display
  • Wrap-around cover
  • 0-1 V analog output

Additional Specs

Resolution

0-2000 ppm range 1 ppm
0-1000 ppm range 1 ppm
0-500 ppm range 1 ppm
0-200.0 ppm range 0.1 ppm
0-100.0 ppm range 0.1 ppm
0-50.0 ppm range 0.1 ppm
0-20.0 ppm range 0.1 ppm
0-5.00 ppm range 0.01 ppm
0-2.00 ppm range 0.01 ppm
0-1.00 ppm range 0.01 ppm

Weight:
8 lb (3.6 kg)

Dimensions:
7" H x 19" W x 12" D
(178 x 483 x 305 mm)

Specifications common to all Interscan gas detection instruments

 

 

Ordering Information:
LD Series Continuous Gas Monitoring Systems and
RM Series Rack Mount Gas Analyzers

GAS

MEASURING
RANGE (ppm)

LD SERIES
Model No.
 †

RM SERIES
Model No.
 †

Br2
bromine
0-20.0
0-5.00
LD70-20.0m
LD70-5.00m
RM70-20.0m
RM70-5.00m
CO
carbon monoxide
0-2000
0-200.0
0-100.0
0-50.0
LD14-2000m
LD14-200.0m
LD14-100.0m
LD14-50.0m
RM14-2000m
RM14-200.0m RM14-100.0m RM14-50.0m
Cl2
chlorine
0-20.0
0-5.00
LD34-20.0m
LD34-5.00m
RM34-20.0m
RM34-5.00m
ClO2
chlorine dioxide
0-20.0
0-5.00
0-2.00
LD33-20.0m
LD33-5.00m
LD33-2.00m
RM33-20.0m
RM33-5.00m
RM33-2.00m
C2H4
ethylene
0-2000
0-200.0
0-20.0
0-5.00
LD07-2000m
LD07-200.0m
LD07-20.0m
LD07-5.00m
RM07-2000m
RM07-200.0m
RM07-20.0m
RM07-5.00m
EtO
ethylene oxide
0-50.0
0-20.0
0-5.00
LD20-50.0m
LD20-20.0m
LD20-5.00m
RM20-50.0m
RM20-20.0m
RM20-5.00m
HCHO
formaldehyde
0-20.0
0-2.00
LD16-20.0m
LD16-2.00m
RM16-20.0m
RM16-2.00m
H2NNH2
CH3NHNH2
(CH3)2NNH2
hydrazine(s) ¶
0-20.0
0-2.00
LD18-20.0m
LD18-2.00m
RM18-20.0m
RM18-2.00m
H2
hydrogen
0-2000
0-500
LD02-2000m
LD02-500m
RM02-2000m
RM02-500m
HBr
hydrogen bromide
0-20.0
0-5.00
LD80-20.0m
LD80-5.00m
RM80-20.0m
RM80-5.00m
HCl
hydrogen chloride
0-20.0
0-5.00
LD36-20.0m
LD36-5.00m
RM36-20.0m
RM36-5.00m
HCN
hydrogen cyanide
0-50.0
0-20.0
0-5.00
LD28-50.0m
LD28-20.0m
LD28-5.00m
RM28-50.00m
RM28-20.0m
RM28-5.00m
H2O2
hydrogen peroxide
0-1000
0-200.0
0-50.0
0-5.00
LD09-1000m
LD09-200.0m
LD09-50.0m
LD09-5.00m
RM09-1000m
RM09-200.0m
RM09-50.0m
RM09-5.00m
H2S
hydrogen sulfide
0-500
0-200.0
0-20.0
0-1.00
LD17-500m
LD17-200.0m
LD17-20.0m
LD17-1.00m
RM17-500m
RM17-200.0m
RM17-20.0m
RM17-1.00m
NO
nitric oxide
0-2000
0-200.0
0-20.0
0-5.00
LD54-2000m
LD54-200.0m
LD54-20.0m
LD54-5.00m
RM54-2000m
RM54-200.0m
RM54-20.0m
RM54-5.00m
NO2
nitrogen dioxide

Also known as N2O4
nitrogen tetroxide
0-50.0
0-20.0
0-5.00
LD15-50.0m
LD15-20.0m
LD15-5.00m
RM15-50.0m
RM15-20.0m
RM15-5.0m
O3
ozone
0-50.0
0-20.0
0-5.00
LD48-50.0m
LD48-20.0m
LD48-5.00m
RM48-50.0m
RM48-20.0m
RM48-5.00m
PrO
propylene oxide
0-50.0
0-20.0
0-5.00
LD32-50.0m
LD32-20.0m
LD32-5.00m
RM32-50.0m
RM32-20.0m
RM32-5.00m
SO2
sulfur dioxide
0-200.0
0-50.0
0-20.0
0-5.00
LD24-200.0m
LD24-50.0m
LD24-20.0m
LD24-5.00m
RM24-200.0m
RM24-50.0m
RM24-20.0m
RM24-5.00m

  † These are the new model numbers. Certain other sources may not reflect this system, while the changeover is occurring. If in doubt, specify the gas and the measuring range desired.

  ¶ There is not a separate analyzer available for each of these compounds, and the sensor does not respond equally to all hydrazine species. The analyzer must be calibrated with the specific hydrazine compound of interest.

Special ranges available on request—The panel meter can be factory programmed to display any desired full scale range, within the measuring capability of the instrument.


  

 P.O. Box 2496 • Chatsworth, CA 91313-2496
 TOLL FREE: (800) 458-6153 (US & Canada) • PHONE: (818) 882-2331
 FAX: (818) 341-0642 • E-MAIL: info@gasdetection.com

 Home Page

 Products
     • Arc-Max® Computerized
          Data Acquisition System

     • Automation Based Gas
          Detection Systems

     • Continuous Monitoring-
          Single Point

     • Continuous Monitoring-
          Three Or More Points

     • Continuous Monitoring-
          Two Point

     • Portable Survey
          Monitoring Applications

     • The Halimeter® Measure
          Bad Breath Scientifically

     • TruTrack Data Logger
     • Vikane® Monitor

 Tech Center
     • Common Specifications
     • Ethylene Oxide     
     • FAQ - Instrument
          Troubleshooting

     • Gas Detection
          Applications Primer

     • Gas Detection
          Knowledge Base

     • General Considerations
     • Getting Service
     • How Do I Get Started?
     • Halimeter®
     • Interfering Gas Data
     • Manual Downloads
     • Material Safety Data Sheets
     • PowerPoint Presentations
     • Schematics
     • Sensor Principle of Operation
     • Sensor Response Data
     • Software Downloads
     • Toxnet - HSDB
     • Useful formulae--
          Conversions, etc.


Industry Links

Interscan In The News
     • Magazine Articles

Interscan Photo Gallery

Representatives and
     Distributors Worldwide


Special Interest Items
     • Mike's Comment
          of the Week

     • Cool Site of the Week

 Streaming Media Library

E-mail Us



Sign up here for our newsletter. (Your e-mail address will NEVER be given or sold to any other party)

e-mail
    Subscribe
    Unsubscribe


Copyright ©1996 - 2010
Interscan Corporation.
All rights reserved.

All other trademarks are
the property of their
respective owners.