Interscan’s portable gas analyzers are available for applications including: Br2, CO, Cl2, ClO2, C2H4, ethylene oxide, HCHO, H2, hydrazine, HBr, HCl, HCN, H2O2, H2S, NO, NO2, O3, peracetic acid, propylene oxide, and SO2.

Our portable gas analyzers utilize Interscan’s own patented (US Patent Number 4,017,373) electrochemical voltametric sensors.

4000 Series portable gas analyzer

Click picture for larger image

4000 Series Portable Gas Analyzers

Features

  • An integral sample pump, powered by rechargeable Ni-Cd batteries (supplied), giving up to 10 hours of continuous service
  • Digital readout of concentration in real time
  • Audible and visual alarm
  • Nylon/Cordura carrying case
  • Plug-in “calculator-type” battery charger
  • UL Classified Intrinsically Safe models, for use in hazardous locations—Class I, Groups A, B, C, and D—are available. Please consult factory.
  • Analog output (0-100 mV full scale)

Options

  • Special ranges
  • Special packaging

Additional Specs

Measuring RangeResolution
0-1999 ppm1 ppm
0-1000 ppm1 ppm
0-500 ppm0.1 ppm
0-199.9 ppm0.1 ppm
0-50.0 ppm0.1 ppm
0-19.99 ppm0.01 ppm
0-5.00 ppm0.01 ppm
ppb ranges1 ppb
Resolution of UL Classified analyzers is 2 percent of full scale.
NOTE: Not all measuring ranges are available for all gases. Please refer to specific ordering information, below.

Weight:

4.5 lb (2.0 kg)

Dimensions:

7″ H x 4″ W x 8.875″ D
(178 x 102 x 225 mm)

Specifications common to all Interscan gas detection instruments


Range Table and Ordering Information for 4000 Series Portable Gas Analyzers

GAS
MODEL NO.
STANDARD MEASURING RANGES
(ppm, unless otherwise indicated)
Br2
bromine
4700-19.99m
4700-1999b
0-19.99
0-1999 ppb
CO
carbon monoxide
4140-1999m
4140-500.0m
4140-199.9m
4140-50.0m
0-1999
0-500.0
0-199.9
0-50.0
Cl2
chlorine
4340-19.99m
4340-5.00m
4340-1999b
0-19.99
0-5.00
0-1999 ppb
ClO2
chlorine dioxide
4330-19.99m
4330-1999b
4330-1000b
0-19.99
0-1999 ppb
0-1000 ppb
C2H4
ethylene
4070-1999m
4070-500.0m
4070-199.9m
4070-19.99m
4070-1999b
0-1999
0-500.0
0-199.9
0-19.99
0-1999 ppb
EtO
ethylene oxide
4200-50.0m
4200-19.99m
4200-5.00m
4200-1999b
4200-1000b
0-50.0
0-19.99
0-5.00
0-1999 ppb
0-1000 ppb
HCHO
formaldehyde
4160-19.99m
4160-5.00m
4160-1999b
0-19.99
0-5.00
0-1999 ppb
H2NNH2
CH3NHNH2
(CH3)2NNH2
hydrazine(s) ¶
4180-1999b
4180-1000b
4180-500b
4180-100b
4183UL¤
4186UL¤
4187UL¤
4189UL¤
0-1999 ppb
0-1000 ppb
0-500 ppb
0-100 ppb
0-0.5/0-2
0-2/0-10
0-100/0-2000 ppb
0-100/0-1000 ppb
H2
hydrogen
4020-1999m
4020-199.9m
0-1999
0-199.9
HBr
hydrogen bromide
4800-19.99m
4800-1999b
0-19.99
0-1999 ppb
HCl
hydrogen chloride
4360-19.99m
4360-1999b
4368UL¤
0-19.99
0-1999 ppb
0-10/0-50
HCN
hydrogen cyanide
4280-199.9m
4280-19.99m
4280-1999b
0-199.9
0-19.99
0-1999 ppb
H2O2
hydrogen peroxide
4090-1000m
4090-199.9m
4090-50.0m
4090-19.99m
4090-5.00m
4090-1999b
0-1000
0-199.9
0-50.0
0-19.99
0-5.00
0-1999 ppb
H2S
hydrogen sulfide
4170-50.0m
4170-19.99m
4170-1999b
4170-1000b
4170-500b
4170-200b
0-50.0
0-19.99
0-1999 ppb
0-1000 ppb
0-500 ppb
0-200 ppb
NO
nitric oxide
4540-199.9m
4540-19.99m
4540-1999b
0-199.9
0-19.99
0-1999 ppb
NO2
nitrogen dioxide

Also known as N2O4
nitrogen tetroxide
4150-199.9m
4150-19.99m
4150-1999b
4152UL¤
4154UL¤
0-199.9
0-19.99
0-1999 ppb
0-2/10
0-10/0-50
O3
ozone
4480-19.99m
4480-1999b
0-19.99
0-1999 ppb
PAA
peracetic acid
Also known as peroxyacetic acid
4890-50.0m
4890-19.99m
4890-5.00m
0-50.0
0-19.99
0-5.00
PrO
propylene oxide
4320-199.9m
4320-19.99m
4320-1999b
0-199.9
0-19.99
0-1999 ppb
SO2
sulfur dioxide
4240-50.0m
4240-19.99m
4240-1999b
0-50.0
0-19.99
0-1999 ppb

¶ There is not a separate analyzer available for each of these compounds, and the sensor does not respond equally to all hydrazine species. The analyzer must be calibrated with the specific hydrazine compound of interest.

¤ Indicates the analog meter UL classified intrinsically safe version, which must be ordered in most hypergol monitoring applications.

Special ranges are available on request.