SEARCH

Gas Detection Knowledge Base

Main

Complying with 40 CFR Part 63 subpart WWWWW--National Emission Standards for Hospital Ethylene Oxide Sterilizers

Print
Save to list

Background

In the continuing regulatory assault on ethylene oxide, more rules now apply. Fortunately, these latest statutes are not at all difficult to comply with. The new rule is called "National Emission Standards for Hospital Ethylene Oxide Sterilizers." It was published on 28 December 2007 as 40 CFR Part 63, with particular notice given to subpart WWWWW.

EPA is issuing national emissions standards for new and existing hospital sterilizers that emit hazardous air pollutants and are area sources within the meaning of Clean Air Act section 112(a)(2). The final rule is based on EPA's determination as to what constitutes the generally available control technology or management practices for the hospital sterilizer area source category.

This action is being finalized as part of EPA's obligation to regulate area sources listed for regulation pursuant to Clean Air Act section 112(c)(3).

 

Source Material

Here is a link to the final rule.

Here is a link to subpart WWWWW.

Here is a link to EPA's summary of the regulations.

 

 

Compliance

Our good friends at Honeywell Oxyfume® Sterilants have prepared an explanatory document, with guidelines on how to comply with the new rule. The guidelines would also apply to 100% EtO and cartridge systems.

Honeywell has also prepared an Information Bulletin, that includes a handy table to calculate actual annual ethylene oxide usage, for users of cylinder EtO. A companion document to this is Honeywell's Example Initial Notification of Compliance Status.

The EPA has determined that Andersen sterilizers are effectively exempt from the rule, since in their method, sterilization bags are utilized, and these bags are always fully loaded—thus comprising "fully loaded sterilization units," as are required by Subpart WWWWW.

sterilizers are effectively exempt from the rule, since in their method, sterilization bags are utilized, and these bags are always fully loaded—thus comprising "fully loaded sterilization units," as are required by Subpart WWWWW.

This ruling was made—as it must be—in response to an inquiry submitted by an Andersen customer.




Related Articles
Is It Necessary To Monitor Ozone Around An Ozone Sterilizer?
With the advent, in 2005, of a practical ozone-based sterilizer by TSO 3 , Inc. (Model 125L), and its subsequent installation into sterile processing facilities, ChemDAQ...
Why does Interscan offer a 0-50 ppm measuring range for ethylene oxide?
Sometimes, we are asked about the 0-50 ppm measuring range offered on our ethylene oxide (EtO) instruments. After all, a founding principle for direct-reading instruments,...
Our commentary on OSHA's Small Business Guide for Ethylene Oxide
On 30 April 2009, OSHA released a comprehensive document entitled "Small Business Guide for Ethylene Oxide." This new publication is available as a spiffy pdf...

 


  

 P.O. Box 2496 • Chatsworth, CA 91313-2496
 TOLL FREE: (800) 458-6153 (US & Canada) • PHONE: (818) 882-2331
 FAX: (818) 341-0642 • E-MAIL: info@gasdetection.com

 Home Page

 Products
     • Arc-Max® Computerized
          Data Acquisition System

     • Automation Based Gas
          Detection Systems

     • Continuous Monitoring-
          Single Point

     • Continuous Monitoring-
          Three Or More Points

     • Continuous Monitoring-
          Two Point

     • Portable Survey
          Monitoring Applications

     • The Halimeter® Measure
          Bad Breath Scientifically

     • TruTrack Data Logger
     • Vikane® Monitor

 Tech Center
     • Common Specifications
     • Ethylene Oxide     
     • FAQ - Instrument
          Troubleshooting

     • Gas Detection
          Applications Primer

     • Gas Detection
          Knowledge Base

     • General Considerations
     • Getting Service
     • How Do I Get Started?
     • Halimeter®
     • Interfering Gas Data
     • Manual Downloads
     • Material Safety Data Sheets
     • PowerPoint Presentations
     • Schematics
     • Sensor Principle of Operation
     • Sensor Response Data
     • Software Downloads
     • Toxnet - HSDB
     • Useful formulae--
          Conversions, etc.


Industry Links

Interscan In The News
     • Magazine Articles

Interscan Photo Gallery

Representatives and
     Distributors Worldwide


Special Interest Items
     • Mike's Comment
          of the Week

     • Cool Site of the Week

 Streaming Media Library

E-mail Us



Sign up here for our newsletter. (Your e-mail address will NEVER be given or sold to any other party)

e-mail
    Subscribe
    Unsubscribe


Copyright ©1996 - 2010
Interscan Corporation.
All rights reserved.

All other trademarks are
the property of their
respective owners.