Interscan’s GasD 8000 portable gas analyzers represent a complete reimagining of our earlier flagship products, dating back to 1975—which defined how instrument-based toxic gas detection was performed.
GasD 8000 Series models are available for: Br2, CO, Cl2, ClO2, C2H4, ethylene oxide, HCHO, H2, hydrazine, HBr, HCl, HCN, H2O2, H2S, NO, NO2, O3, peracetic acid, propylene oxide, and SO2. And, of course, use the finest electrochemical sensors.
Features
-
- An integral sample pump, powered by rechargeable Lithium-Ion batteries, giving up to 8 hours of continuous service
- Digital readout of concentration, along with real time graphics display and integral data logging
- Audible and visual alarm
- Analog output (4-20 mA and 0-2.5 V)
GasD 8000 Specifications
Accuracy: ±2% of reading ±1 least significant digit
Display: Sunlight visible transflective LCD
Operating environment: 32°F – 113°F (0°C – 45°C) ; 0-90% relative humidity
Internal Battery: Rechargeable Lithium-Ion (5000 mAh)
Data Logging: Via integral SD card
Dimensions: 5½ in H x 8¼ in W x 10 in D (140 x 210 x 254 mm) Includes body and legs
Weight: 6.5 lb (2.95 kg)
Enclosure: Anodized aluminum
Power (when plugged in): Universal AC outlet adapter. Rated voltage 100-240V, 50/60hz, USB A. Total output: 5V, 2400 mA or higher.
Calibration: Against standard gas mixture, or via Interscan’s SENSOR EXPRESS®
Weight: 6.5 lb (2.95 kg)
Dimensions: 5.5 in H x 8.25 in W x 10 in D (140 x 210 x 254 mm)
Range Table and Ordering Information for 8000 Series Portable Gas Analyzers
GAS
|
MODEL NO.
|
STANDARD MEASURING RANGES
(ppm, unless otherwise indicated) |
Br2 bromine |
8700-20.00m
8700-2000b |
0-20.00
0-2000 ppb |
CO carbon monoxide |
8140-2000m
8140-500.0m 8140-200.0m 8140-50.0m |
0-2000
0-500.0 0-200.0 0-50.0 |
Cl2 chlorine |
8340-20.00m
8340-5.00m 8340-2000b |
0-20.00
0-5.00 0-2000 ppb |
ClO2 chlorine dioxide |
8330-20.00m
8330-2000b 8330-1000b |
0-20.00
0-2000 ppb 0-1000 ppb |
C2H4 ethylene |
8070-2000m
8070-500.0m 8070-200.0m 8070-20.00m 8070-2000b |
0-2000
0-500.0 0-200.0 0-20.00 0-2000 ppb |
C2H4O aka EO or EtO ethylene oxide |
8200-50.0m
8200-20.00m 8200-5.00m 8200-2000b 8200-1000b |
0-50.0
0-20.00 0-5.00 0-2000 ppb 0-1000 ppb |
HCHO formaldehyde |
8160-20.00m 8160-5.00m 8160-2000b |
0-20.00 0-5.00 0-2000 ppb |
H2NNH2 CH3NHNH2 (CH3)2NNH2 hydrazine(s) ¶ |
8180-2000b
8180-1000b 8180-500b 8180-100b |
0-2000 ppb
0-1000 ppb 0-500 ppb 0-100 ppb |
H2 hydrogen |
8020-2000m
8020-200.0m |
0-2000
0-200.0 |
HBr hydrogen bromide |
8800-20.00m
8800-2000b |
0-20.00
0-2000 ppb |
HCl hydrogen chloride |
8360-20.00m
8360-2000b |
0-20.00 0-2000 ppb |
HCN hydrogen cyanide |
8280-200.0m
8280-20.00m 8280-2000b |
0-200.0
0-20.00 0-2000 ppb |
H2O2 hydrogen peroxide |
8090-1000m 8090-200.0m 8090-50.0m 8090-20.00m 8090-5.00m 8090-2000b |
0-1000 0-200.0 0-50.0 0-20.00 0-5.00 0-2000 ppb |
H2S hydrogen sulfide |
8170-50.0m
8170-20.00m 8170-2000b 8170-1000b 8170-500b 8170-200b |
0-50.0
0-20.00 0-2000 ppb 0-1000 ppb 0-500 ppb 0-200 ppb |
NO nitric oxide |
8540-200.0m
8540-20.00m 8540-2000b |
0-200.0
0-20.00 0-2000 ppb |
NO2 nitrogen dioxide Also known as N2O4 nitrogen tetroxide |
8150-200.0m 8150-20.00m 8150-2000b |
0-200.0 0-20.00 0-2000 ppb |
O3 ozone |
8480-20.00m
8480-2000b |
0-20.00
0-2000 ppb |
C2H4O3 aka PAA peracetic acid Also known as peroxyacetic acid |
8890-50.0m
8890-20.00m
8890-5.00m
|
0-50.0
0-20.00
0-5.00
|
C3H6O aka PO or PrO propylene oxide |
8320-200.0m
8320-20.00m 8320-2000b |
0-200.0
0-20.00 0-2000 ppb |
SO2 sulfur dioxide |
8240-50.0m
8240-20.00m 8240-2000b |
0-50.0
0-20.00 0-2000 ppb |